Electrostatic Discharge

The Importance of Personnel Grounding Testers

We already know that in an ESD Protected Area (EPA) all surfaces, objects, people and ESD Sensitive Devices (ESDs) are kept at the same potential which is achieved by using ‘groundable’ materials that are then linked to ground. We have also learnt that the most common personnel grounding device to link people to ground are wrist straps. People who are moving around should instead wear ESD footwear.

So how do you know if your wrist straps and ESD footwear are working properly? Excellent question! And one we’ll answer in today’s post so let’s jump right in!

Purpose of Personnel Grounding Testers

Wrist straps and ESD footwear should be part of your Verification Plan. Each component in an EPA plays a vital part in the fight against electrostatic discharge (ESD). If just one component is not performing correctly, ESD sensitive devices can be damaged, potentially costing your company thousands of dollars.

Wrist straps and ESD footwear can fail and damage cannot always be detected by visual inspection. Just by looking at the items you would not know if they still provide sufficient protection. Personnel grounding testers should be used to provide feedback to verify the functionality of an operator’s wrist strap and/or footwear.

Your Personnel Grounding Checklist - Wear, Verify, Log, Handle
Your Personnel Grounding Checklist

Your Personnel Grounding Checklist:

  1. Wear your personnel grounding equipment such a wrist strap and/or footwear
  2. Verify your personnel grounding system using a wrist strap and/or footwear tester. Wrist straps and footwear, need to be tested at least daily before handling ESD sensitive devices and should be worn while checking.
  3. Log a record of each test. Records should be kept for quality control purposes.
  4. Handle ESD sensitive components ONLY if your wrist strap and/or footwear pass(es) the test.

Types of Personnel Grounding Testers

Personnel grounding testers can be purchased in two configurations:

  • Wrist strap tester
  • Wrist strap and footwear tester

As wrist straps are the most commonly used personnel grounding device to ground operators, you will find a lot of testers on the market that check wrist straps only. Combined wrist strap and footwear testers will verify your wrist straps AND footwear.

In addition to WHAT the testers verify, you will also be faced with a wide range of devices differing in HOW they test. Below you will see a (by no means complete) list of options:

  • Continuous and split footplate: You will find testers with a continuous footplate which require each foot to be tested separately one after the other. Dual-footplate or independent footwear testers feature a split footplate which allows the unit to verify both feet independently at the same time. This can be an efficient time-saver if you have a number of operators in your company who are required to check their personnel grounding devices.
  • Portable, wall-mountable and fitted testers: Portable battery-powered (predominantly) wrist strap testers are suitable for small labs or for supervisors to spot-check workers and ensure compliance. Wall-mountable units are generally supplied with a wall plate which attaches to a wall; the tester is then mounted on to the wall plate. Some personal grounding devices are accompanied by a stand (and built-in footplate) which allow for a more freely positioning of the unit within a room.
  • Relay terminal: A few testers on the market are fitted with a relay terminal (electrically operated switch) that can be integrated with electronic door locks, turnstiles, lights, buzzers, etc. This can be of advantage if companies only want to allow personnel in an EPA that have passed their wrist strap and/or footwear test.
  • Data acquisition: A growing number of personnel grounding devices allow for test activity data to be logged in a database. The units link to a computer which records operator identification, test results, resistance measurements, time and more. Paperless data can enhance operator accountability, immediately identifying problems while reducing manual logging and auditing costs.

Operation of Personnel Grounding Testers

Wrist strap testing:

If you are not using a continuous or a constant monitor, a wrist strap should be tested at least daily. This quick check can determine that no break in the path-to-ground has occurred. Wrist straps should be worn while they are tested. This provides the best way to test all three components:

  • the wrist band
  • the ground cord (including the resistor)
  • the interface (contact) with the operator’s skin
The SCS Combo Wrist Strap/ Footwear Tester
The SCS Combo Tester can be used to test wrist straps – more information

To ensure that the resistance to ground of personnel is within specification it is important to measure the entire system (i.e., wrist strap, person, and ground connection). The wrist strap system test method is described in ANIS/ESD S1.1. In general, the test method measures the resistance of the ground cord, wristband or cuff, and the interface of the band or cuff of the wearer.” [Handbook ESD TR20.20 Clause 8.2 Wrist Strap System]

The wrist strap system should be tested daily to ensure proper electrical resistance. Nominally, the upper resistance reading should be < 35 megohms or a user-defined resistance. Daily test records can provide evidence of conformity. Daily testing may be omitted if continuous monitors are used.” [ANSI/ESD S1.1 Clause A3. Frequency of System Testing]

If the wrist strap tester outputs a FAIL test result, stop working and test the wrist band and cord individually to find out which item is damaged. Replace the bad component and repeat the test. Obtain a PASS test result before beginning work. For more information on troubleshooting failed wrist straps, check this post.

Footwear testing:

If you are using a flooring / footwear system as an alternative for standing or mobile workers, ESD footwear should be tested independently at least daily while being worn. Proper testing of foot grounders involves the verification of:

  • the individual foot grounder
  • the contact strip
  • the interface between the contact strip and the operator’s perspiration layer

a) Place the foot grounders on the user’s shoes per the manufacturer’s instructions.
b) Place the left foot on the floor plate and touch the body contact area on the tester with one hand. Activate the tester per the manufacturer’s instructions.
c) Remove the left foot from the floor plate.
d) Repeat steps b and c with the right foot.
[ANSI/ESD SP9.2 Clause 6.2.2 Procedure (Integrated Tester)]

The SCS Dual Combination Tester is used to test wrist straps and footwear
The SCS Dual Combination Tester is used to test wrist straps and footwear – more information

If the footwear tester outputs a FAIL test result, stop working, and test the foot grounder and contact strip individually to find out which item is damaged. Replace the foot grounder. Obtain a PASS test result before beginning work.

Conclusion

Wrist straps and footwear need to be tested at least daily before handling any ESD sensitive devices. Personnel grounding devices need to be worn for verification using a wrist strap and/or footwear tester.

A record of each test has to be kept for quality control purposes.

Only handle ESD sensitive components if your wrist strap and/or footwear pass(es) the test.

 

Controlling ESD/EOS During the Soldering Process

When the tip of a soldering iron comes into direct electrical contact with the pins of a sensitive component, there is a danger of voltage and/or current signal transfer between:

  • the grounded iron tip and the grounded PC board,
  • the ungrounded iron tip and the grounded PC board,
  • the grounded iron tip and the ungrounded PC board.

This can cause Electrical Overstress (EOS) and Electrostatic Discharge (ESD).

What is Electrical Overstress (EOS) and why is it important to detect?

EOS is the exposure of a component or PCB board to a current and/or voltage outside its operational range. This absolute maximum rating (AMR) differs from one device to the next and needs to be provided by the manufacturer of each component used during the soldering process. EOS can cause damage, malfunction or accelerated aging in sensitive devices.

ESD can be generated if a component and a board have different potentials and the voltage transfers from one to the other. When such an event happens, the component goes through EOS. ESD can influence EOS, but EOS can also be influenced by other signals.

Many people are familiar with Electrostatic Discharge (ESD) which is caused by the spontaneous discharge between two materials that are at different levels of ElectroStatic potential. Once electrostatic potential between the two materials is balanced, the ESD event will stop.

An EOS event on the other hand is created by voltage and/or current spikes when operating equipment; it can therefore last “as long as the originating signal exists”. [Source] The potentially never-ending stimulus of EOS is what makes it such a big concern in the electronics industry. Even though the voltage levels are generally much lower compared to an ESD event, applying this smaller voltage combined with a larger peak current over a long period of time will cause significant damage.

The high temperatures during an EOS event (created by the high current) can lead to visible EOS damage.

For more information on EOS and the differences to ESD, check-out this post.

Sources of EOS during the Soldering Process

When soldering components, it’s the tip of the soldering iron that comes into contact with the potentially sensitive device. Therefore, many people assume the soldering tip is the cause of ESD/EOS. However, the soldering iron and its tip are just some of the components used at a workbench. Other components on the bench like tweezers, wiring, test equipment, etc. can also be sources of ESD/EOS as they come into contact with the component or board.

There are many sources of EOS during the soldering process, which can include:

  • Loss of Ground
    The tip of an ungrounded soldering iron can accumulate a voltage of up to ½ of the iron’s supply voltage. It can be caused within the soldering iron itself or in power outlets.
  • Noise on Ground
    If a noise signal exists on ground, the tip of the solder iron will carry noise, too. These high-frequency signals, or electromagnetic interference (EMI), are disturbances that affect an electrical circuit, due to either electromagnetic induction or electromagnetic radiation emitted from an external source.
  • Noise on Power Lines
    Noise not only generates via ground but in power lines, too. Transformers and power supplies that convert voltages to 24V are the main culprit. They regularly carry high-frequency spikes which end up on the tip of the soldering iron.
  • Power Tools
    Although not technically related to the soldering process itself, it’s worth mentioning that the tips of power tools (e.g. electric screwdrivers) may not be properly grounded during rotation. This can result in high voltage on the tip itself.
  • Missing/Inadequate ESD Protection
    ESD can be a cause of EOS damage. Therefore, it is essential to have proper ESD Protection in place. A voltage on the operator or the PCB board can otherwise lead to an ESD Event and expose the components on the PCB to EOS.

Detecting EOS during the Soldering Process

EOS/ESD events can be detected, measured, and monitored during the soldering process using a variety of diagnostic tools.

Diagnostic Tools

  • SCS CTM051 Ground Pro Meter
    The SCS CTM051 Ground Pro Meter is a comprehensive instrument that measures ground impedance, AC and DC voltage on the ground as well as the presence of high-frequency noise or electromagnetic interference (EMI) voltage on the ground. It will alert if the soldering iron tip has lost its ground or has EMI voltage induced into the tip from an internal source on the soldering iron or from an EMI noisy ground or power lines.

    CTM051
    The SCS CTM051 Ground Pro Meter
  • SCS CTM048 EM Eye – ESD Event Meter
    The SCS CTM048 EM Eye – ESD Event Meter paired with the SCS CTC028 EM Field Sensor is a diagnostic tool for the detection and analysis of ESD events and electromagnetic fields and can identify sources of harmful ESD Events and electromagnetic interference (EMI).

    CTM048-21
    The SCS CTM048 EM Eye – ESD Event Meter paired with the SCS CTC028 EM Field Sensor

EOS Continuous Monitors

  • SCS CTC331-WW Iron Man® Plus Workstation Monitor
    The SCS CTC331-WW Iron Man® Plus Workstation Monitor is a single workstation continuous monitor which continuously monitors the path-to-ground integrity of an operator and conductive/dissipative worksurface and meets ANSI/ESD S20.20.The Iron Man® Plus Workstation Monitor is an essential tool when it comes to EOS detection. The unit is capable of detecting EOS on boards and alarms if an overvoltage (±5V or less) from a tool such as a soldering iron or electric screwdriver is applied to a circuit board under assembly.

    CTC331-WW
    The SCS CTC331-WW Iron Man® Plus Workstation Monitor

Data Acquisition

  • SCS Static Management Program
    SCS Static Management Program (SMP) continuously monitors the ESD parameters throughout all stages of manufacturing. It captures data from SCS workstation monitors, ground integrity monitors for equipment, ESD event and static voltage continuous monitors and provides real-time data of manufacturing processes.The SCS 770063 EM Aware Monitor, which is part of SMP, can help during the soldering process by monitoring ESD events and change of static voltage that may result in EOS. The EM Aware alarms (visual and audibly) locally and sends data to the database of the SMP system if any of the ESD parameters are detected to be higher than user-defined limits.

    770063.jpg
    The SCS 770063 EM Aware Monitor

Eliminating EOS during the Soldering Process

Once the source of ESD/EOS is known, there are many things that can be done to prevent it in the first place: 

1. Managing Voltage on a PCB board

PCB boards contain isolated conductors and non-conductive (insulative) components. The only way to handle voltage on a PCB board is neutralizing potential static charges through ionization. An ionizer creates great numbers of positively and negatively charged ions. Fans help the generated ions flow over the work area to neutralize static charges (or voltage) on a PCB board in a matter of seconds.

For more information on ionization and how to choose the right type of ionizer for your application, please read these posts.

2. Managing Voltage on an Operator

Static voltage on an operator can be eliminated through proper grounding using a workstation monitor, e.g. WS Aware or Iron Man Plus Monitor, and proper grounding hardware. Sitting personnel are required to wear wrist straps. A wrist strap consists of a conductive wristband which provides an electrical connection to skin of an operator, and a coil cord, which is connected to a known ground point at a workbench, a tool or a continuous monitor. While a wrist strap does not prevent generation of voltages, its purpose is to dissipate these voltages to ground as quickly as possible.

Sitting personnel can also use continuous monitors – not only is the operator grounded through the continuous monitor, but they also provides a number of additional advantages:

  • Immediate feedback should a wrist strap fail
  • Monitoring of operators and work stations
  • Detection of split-second failures
  • Elimination of periodic testing

This post provides more details on continuous monitors.

Moving or standing personnel are grounded via a flooring/footwear system. ESD Footwear (e.g. foot grounders) are designed to reliably contact grounded ESD flooring and provide a continuous path-to-ground by removing electrostatic voltages from personnel.

3. Managing Current

One solution is the “re-routing of ground connection and separation of “noisy” ground from a clean one” as “connecting soldering iron and the workbench to the “quiet” ground often result in lower level of transient signals.“. [Source]

This will greatly reduce the high-frequency noise that could cause EOS damage.

If the noise on power lines and ground cannot be reduced manually, then the use of noise filters becomes necessary to reduce the risk of EOS exposure during the soldering process. Utilizing these filters suppresses the noise on power lines and will allow the solder iron to use “clean” power only.

In his papers, Vladimir Kraz, explains the set-up of a soldering station using a noise filter in more detail.

Noise-Filter
Soldering Iron with Power Line EMI Filter [Source]

Conclusion

During the soldering process, current and voltage spikes between the solder tip and PCB can cause ESD/EOS. Sources are varied and can include:

  • Loss of Ground
  • Noise on Ground
  • Noise on Power Lines
  • Power Tools
  • Missing/Inadequate ESD Protection

ESD/EOS can be identified and controlled using diagnostic tools. SCS offers a number of tools that can detect current, voltage and EMI – all potentially leading to ESD and EOS.

Once the source of ESD/EOS is known, the next step is eliminating the source:

  • Managing voltage on a PCB board using ionizers.
  • Managing voltage on an operator using workstation monitors or foot grounders.
  • Managing current using noise filters.
  • Managing voltage on materials at the work bench.
  • Managing ESD generation during specific processes.
  • Managing grounding.

 For more information regarding this topic, please see below for additional references.

References:

How to Reduce the Risk of Damaging ESD Sensitive Devices in Critical Applications

Do your employees handle ESD-sensitive high-end components that are expensive to replace if they failed? If so, reducing the possibility of ESD damage is an important part of an ESD control program. Today’s blog post will look at one option of protecting your critical applications: Dual-Wire Wrist Straps.

Introduction

In an ESD Protected Area (EPA), all surfaces, objects, people and ESD sensitive devices (ESDs) are kept at the same electric potential. This is achieved by using only ‘groundable’ materials that are then linked to ground.

This is in line with the requirements of ANSI/ESD S20.20: “The Organization shall prepare an ESD Control Program Plan that addresses each of the requirements of the Program. Those requirements include:
– Training
– Product Qualification
– Compliance Verification
– Grounding / Equipotential Bonding Systems
– Personnel Grounding
– ESD Protected Area (EPA) Requirements
– Packaging Systems
– Marking

[ANSI/ESD S20.20 clause 7.1 ESD Control Program Plan]

Wrist Straps

Wrist straps are the most common personnel grounding device and are used to link people to ground. They are required if the operator is sitting.

A wrist strap is made up of two components:

  • A wrist band that is worn comfortably around your wrist and
  • A coiled cord that connects the band to a Common Grounding Point.

wristbandComponents of a Wrist Strap 

Dual-Wire Wrist Straps

Dual-Wire Wrist Straps have two conductors (compared to single-wire monitors which have only one conductor inside the insulation of the coiled cord). They offer a reduced risk of damaging ESD sensitive devices because if one conductor is severed or damaged, the operator still has a reliable path-to-ground with the second conductor. For that reason, they dual-wire wrist straps are generally used in critical applications.

Advantages of using Dual-Wire Wrist Straps:

  • Elimination of intermittent failures
  • Extension of wrist strap lifespan
  • Compatible with high performance continuous monitors

 2231
The MagSnap 360™ Dual-Wire Wrist Strap and Coil Cord –
more information

Dual-Wire Continuous Monitors

For maximum benefit, dual-wire wrist straps should be used together with dual-wire continuous monitors. Instead of connecting a coil cord directly to a common grounding point, the operator connects to a continuous monitor. The operator is grounded through the continuous monitor and the operator-to-ground connection is monitored.

The monitors provide operators with instant feedback on the status and functionality of their wrist strap and/or workstation. Continuous monitors detect split-second failures when the wrist strap is still in the “intermittent” stage. This is prior to a permanent “open” which could result in damage to ESD sensitive components. The “intermittent” stage is characterized by sporadic failures as the cord is not completely severed. Once the cord is fully split, the “open” stage is reached.

WS-Aware-UseThe WS Aware Dual-Wire Workstation Monitor – more information


Since people are one of the greatest sources of static electricity and ESD, proper grounding is paramount. One of the most common ways to ground people is with a wrist strap. Ensuring that wrist straps are functional and are connected to people and ground is a continuous task.” “While effective at the time of testing, wrist strap checker use is periodic. The failure of a wrist strap between checks may expose products to damage from electrostatic charge. If the wrist strap system is checked at the beginning of a shift and subsequently fails, then an entire shift’s work could be suspect.” “Wrist strap checkers are usually placed in a central location for all to use.  Wrist straps are stressed and flexed to their limits at a workstation.  While a wrist strap is being checked, it is not stressed, as it would be under working conditions.  Opens in the wire at the coiled cord’s strain relief are sometimes only detected under stress.“ [ESD TR 12-01 Technical Report Survey of Constant (Continuous) Monitors for Wrist Straps]

Resistance (or dual-wire) constant monitors are “… used with a two wire (dual) wrist strap. When a person is wearing a wrist strap, the monitor observes the resistance of the loop, consisting of a wire, a person, a wristband, and a second wire.  If any part of the loop should open (become disconnected or have out of limit resistance), the circuit will go into the alarm state.” “While the continuity of the loop is monitored, the connection of the wrist strap to ground is not monitored.” “There are two types of signals used by resistance based constant monitors; steady state DC and pulsed DC.  Pulsed DC signals were developed because of concerns about skin irritation.  However, pulse DC units introduce periods of off time (seconds) when the system is not being monitored.“ [ESD TR 12-01 Technical Report Survey of Constant (Continuous) Monitors for Wrist Straps]

Conclusion

Dual Polarity Technology provides true continuous monitoring of wrist strap functionality and operator safety according to accepted industry standards. Dual-wire systems are used to create redundancy. In critical applications redundancy is built-in to have a backup if the primary source fails. With dual-wire wrist straps the redundancy is there as a protection rather than an alternative. If you are monitoring your dual-wire wrist strap and one wire fails, then the unit will alarm. You will still be grounded by the other wire, so there will be a significantly reduced risk of damaging ESD sensitive components if you happen to be handling them when the wrist strap fails. The wrist strap still needs to be replaced immediately.

And there you have it: dual-wire wrist straps together with dual-wire continuous monitors offer better protection than intermittent monitoring or testing if you have a critical application.

Check-out the SCS Wrist Strap Selection Guide and Workstation Monitor Selection Guide to find the correct products for your application.

An Introduction to Wrist Straps

We get a lot of inquiries regarding wrist straps: what they do, why there are different types, how they are used, etc. So, the purpose of today’s blog post is to answer all those questions for you. If there is something we did not cover in the blog post make sure you ask us in the comments!
Let’s get started!

Introduction
The ESD Standard S20.20 requires “an ESD Control Program Plan that addresses each of the requirements of the Program. Those requirements include:

  • Training
  • Product Qualification
  • Compliance Verification
  • Grounding/Equipotential Bonding Systems
  • Personnel Grounding
  • ESD Protected Area (EPA) Requirements
  • Packaging Systems
  • Marking”
    [ANSI/ESD S20.20 clause 7.1 ESD Control Program Plan]

The most common personnel grounding device is a wrist strap which is used to connect people to ground.
A wrist strap in general is a conductive wristband which provides an electrical connection to skin of an operator and, in turn, is connected to a known ground point at a workbench or a tool. While a wrist strap does not prevent generation of charges, its purpose is to dissipate these charges to ground as quickly as possible. Wrist straps are required if the operator is sitting. They are not necessary if an operator is wearing two foot grounders on a conductive grounded floor and doesn’t lift both heels/toes at the same time. As some people lift both feet off the ground while seated, wrist straps are essential for sitting personnel.
A wrist strap is made up of two components:

  • a wristband that is worn comfortably around your wrist and
  • a coil cord that connects the band to ground.

Wristband and coil cord of a wrist strapWristband and coil cord of a wrist strap

The key to the wrist strap is the intimate contact of the conductive band to the skin and of course the coil cord connecting to ground. It doesn’t matter if the contact point to your body is on your wrist, finger, forearm, ankle, etc., as long as it is in direct contact with your skin. The skin is electrically continuous over your whole body. The wrist is just a convenient place to couple the band to.

Styles of Wrist Straps
Operators can choose between elastic and metal wristbands:

  • Elastic wristbands are the most popular wristband as they are comfortable to wear and easy to adjust. Compared to metal wristbands they are also less expensive.
  • Some people prefer metal wristbands as they are generally longer lasting and easier to clean.

The key to personnel grounding is to have an adequate path to ground so that there is never a potential difference with respect to ground on the human body for longer than 150 milliseconds (ms) body movement time. Such rapid grounding is accomplished well by elastic or metal wrist straps. So, in terms of their effectiveness to protect against ESD, there is no difference between elastic and metal wristbands.

Both elastic and metal wristbands are (to a certain degree) adjustable. Metal wristbands offer less adjustment, so you will find those are generally available in different sizes depending on the circumference of your wrist. However, you are still able to adjust metal wristbands if you need a tighter/looser fit.
To adjust your wristband, follow the below steps:
1. Elastic wristbands:

  • Open the clasp by pulling upward on the “tail” of material that extends out from the clasp.
  • Tighten or loosen the elastic material through the clasp until the wristband fits snug but comfortably.
  • We recommend that you close the clasp and wear the band with the excess tail extended for a day to be sure the adjustment is snug, comfortable, and has the proper electrical contact with the skin before cutting.
  • Test the wrist strap system to be sure of proper electrical resistance and skin contact.
  • When you are ready to cut off excess material, mark with a pencil where excess material is to be trimmed.
  • Remove band from wrist. Open clasp. Cut off strip excess material about 1/4″ short of pencil mark so that the end of material is concealed by cap. This will eliminate the possibility of frayed ends.
  • Close clasp and use as a fixed elastic wristband.

Adjusting an elastic wristbandAdjusting an elastic wristband

2. Metal wristbands:

  • Insert the link end of the wristband into the slotted opening on the cap. Insert it at a downward angle to allow the links to slide inside the channel in the backplate.
  • Change the size of the band by sliding the links in or out of the stainless steel backplate. For extra small size, you can cut off excess links with cutters.
  • Lock the links into place by pulling down on the band, seating the band securely over the lip on the edge of the backplate.
  • Test the wrist strap system to be sure of proper electrical resistance and skin contact.

Adjusting a metal wristbandAdjusting a metal wristband

1 megohm Safety Resistors
The purpose of the 1 megohm resistor found in series with wrist straps is solely to provide safety to the human body by limiting the amount of current that could be conducted through the body. The 1 megohm resistor is designed to limit the current to 250 microamps at 250 Volts rms AC. This is just below the perception level (and a bit before the nervous system goes awry) of most people. Physical perception of current traveling in/on the body varies depending on size, weight, water content, skin conditions, etc. Remember that the termination of the coil cord with the 1 megohm resistor must always be connected to the operator.
Such safety resistors are built into the wrist straps themselves and also in such wrist strap monitors as WS Aware, Iron Man® Plus and Ground Man Plus manufactured by SCS. 

Typical Problems with Wrist Straps
Some of the typical problems with proper grounding of an operator using a wrist strap are:

  • worn out wrist strap which no longer has good electrical properties
  • stretched out wrist strap which doesn’t make good electrical contact with the skin
  • loosely-worn wrist strap which doesn’t make good electrical contact with the skin either
  • dry skin of an operator increasing electric resistance of a contact beyond specification
  • improper placement of a wrist strap, such as over the cuff of the garment

Also, another issue we often see is that wrist strap users connect their wrist cord to a stud on their ESD protective mat. This process is not recommended as it can increase the total system resistance to ground to over the 35 megohm limit required by ANSI/ESD S20.20 table 2.

Testing of Wrist Straps
Wrist straps need to be checked regularly to ensure they are faultless and ground the operator properly. Wrist straps should be worn while they are tested. This provides the best way to test all three components: the wristband, the ground cord (including the resistor) and the interface with the operator’s skin.
Wrist straps need to be checked before each use. Periodic testing is not required if continuous monitors are used. They provide instant feedback should the wrist strap fail while handling ESD sensitive devices.

Verifying a wrist strap using a wrist strap/footwear testerVerifying a wrist strap using a wrist strap/footwear tester

If the wrist strap tester outputs a FAIL test result, stop working. Test the wristband and cord individually to find out which item is damaged. There are some methods to troubleshoot your wrist straps. First make sure your tester is properly adjusted and calibrated.

If the operator and wrist strap system fails low:

  • Make sure that the person is not directly connected to ground via another path, i.e., touching a grounded metal structure.
  • The most common cause of a fail low is a shorted resistor in the wrist strap coil cord. Replace the coiled cord with a new one and repeat the test.

If the operator and wrist strap system fails high:

  • Make sure the coiled cord has a secure connection both the banana jack/socket to tester and the stud snap to wrist strap buckle.
  • Ensure there is continuity in the coiled cord (you can test with an ohmmeter).
  • Remove the wrist strap and hold the bottom part of the band tightly between the operator’s thumb and index finger and test. If the test fails high, the band may be soiled and needs cleaning or the buckle to band connection may be suspect. Either replace the band or clean and then retest.
  • If the above test is okay, then the skin of the operator’s wrist may be too dry. Apply ESD lotion to the wrist to re-moisturize the skin thereby increasing its conductivity. Retest. Operators with dryer skin should wear metal banded wrist straps to minimize the contact resistance. If their skin is very dry, application of an ESD lotion may be required as part of their donning process.

You need to obtain a PASS test result before beginning work.

Now that we’ve covered the basics of wrist straps, we will dive into the different types of wrist straps – but that will have to wait until next time as this post is already very long. Stay tuned!

The importance of employees in the fight against ESD

People pose the biggest threat to ESD sensitive components. However, when properly trained, operators can become the key weapon in the fight against ESD. Every person coming into contact with ESD sensitive items should be able to prevent ESD related problems before they occur or provide immediate action when they do occur. Today’s blog post will explain in detail the role operators play in ESD Protection and how your company can support them in the fight against ESD.

Introduction
As an employee, the invisible threat of ESD should be of great concern to you. ESD damage can significantly reduce your company’s profitability. This may affect your company’s ability to compete in the marketplace, your profit sharing and even your employment. Everyone likes to take pride in their work, but without proper ESD controls, your best efforts may be destroyed by ElectroStatic discharges that you can neither feel nor see.

motherboard doctors
People are often a major factor in the generation of static charges

Perhaps the most important factor in a successful static control program is developing an awareness of the “unseen” problem. People are often a major factor in the generation of static charges. Studies have shown that personnel in a manufacturing environment frequently develop 5000 volts or more by just walking across the floor. This is “tribocharging” produced by the separation of their shoes and the flooring as they walk.
A technician seated at a non-ESD workbench could easily have a 400-500 volt charge on his or her body caused not only by friction or tribocharging but additionally by the constant change in body capacitance that occurs from natural movements. The simple act of lifting both feet off the floor can raise the measured voltage on a person by as much as 500-1000 volts.
Educating your personnel is therefore an essential basic ingredient in any effective static control program. A high level of static awareness must be created and maintained in and around the ESD protected area. Once personnel understand the potential problem, it might help to reinforce this understanding by hanging up a few static control posters in strategic locations. No technician needs an unprotected person wandering over and touching things on the service bench.

The invisible enemy
The biggest issue with ElectroStatic discharges is that you can neither see nor feel the threat. Daily life has other examples of hidden enemies where careful procedures must be followed to regularly obtain positive results. One example is sterilization which combats germs and contamination in hospitals.
Damage caused by invisible and undetectable events can be understood by comparing ESD damage to medical contamination of the human body by viruses or bacteria. Although invisible, they can cause severe damage. In hospitals, the defense against this invisible threat is extensive contamination control procedures including sterilization.

A medical team performing an operation
Would you consider having surgery in a contaminated operating room?

We are aware of the benefits of sterilization in medicine. We must develop the same attitude towards ESD control and “sterilize” against its contamination. Just as you would never consider having surgery in a contaminated operating room, you should never handle, assemble or repair electronic assemblies without taking adequate measures against ESD. For the hospital to sterilize most of the instruments is not acceptable; actually, it may waste money. Every single instrument needs to be sterilized. Likewise, it is not acceptable to protect the ESD sensitive items most of the time. Effective ESD control must occur at each and every step where ESDS items are manufactured, processed, assembled, installed, packaged, labelled, serviced, tested, inspected, transported or otherwise handled.
Everyone handling sensitive components should:

  • recognize ESD threat
  • know what equipment to use, and how to use it
  • know the correct ESD procedures, and work to them
  • know how to check equipment
  • know which packaging to use
  • take corrective actions when required.” [Source]

It is obvious that ESD training of personnel is a prerequisite for a functioning ESD control program.

Training
ESD training needs to be provided to everyone who handles ESD sensitive devices – that includes managers, supervisors, subcontractors, cleaners and even temporary personnel. Training must be given at the beginning of employment (BEFORE getting anywhere near an ESDS) and in regular intervals thereafter.
Initial and recurrent ESD awareness and prevention training shall be provided to all personnel who handle or otherwise come into contact with any ESDS [ESD sensitive] items. Initial training shall be provided before personnel handle ESDS items. The type and frequency of ESD training for personnel shall be defined in the Training Plan. The Training Plan shall include a requirement for maintaining employee training records and shall document where the records are stored. Training methods and the use of specific techniques are at the Organization’s discretion. The training plan shall include the methods used by the Organization to verify trainee comprehension and training adequacy.” [ANSI/ESD S20.20-2007 section 7.2]

Training
Training is an essential part of an ESD Control Program

ESD training should include:

  • an introduction to ESD – what it is, what it’s caused by and how to control it
  • how to handle sensitive devices and what precautions to take when coming into contact with them
  • how to identify and mark ESD sensitive items
  • an overview of the ESD Standard.

For operators working in assembly, repair or field service, job specific training will be required, too.
If visitors are entering an EPA, they must possess basic ESD awareness and understand how to use their wrist straps and footwear.

Operator’s safety comes first
One final word of warning: while ESD control is important, it is of secondary importance to employee safety. ElectroStatic charges or static electricity can be everywhere; however, conductors can be effectively grounded and charges removed to ground. A fundamental rule in ESD control is to ground all conductors, including people. BUT: Personnel should not be grounded in situations where they could come into contact with voltage over 250 volts AC.

EOS and ESD

Electrical Overstress, or EOS, has become a widely-used term over the past few years. However, a lot of people are still unsure as to what exactly it is and how it differs from ElectroStatic Discharge (ESD). Today’s blog post is intended to put an end to the confusion.

What is Electrical Overstress?
One huge problem with Electrical Overstress, or EOS, is the fact that people use the phrase in different ways. Up until now there has been no widely recognized definition. A White Paper on EOS published by the Industry Council on ESD Target Levels in 2016 uses the following definition: “An electrical device suffers an electrical overstress event when a maximum limit for either the voltage across, the current through, or power dissipated in the device is exceeded and causes immediate damage or malfunction, or latent damage resulting in an unpredictable reduction of its lifetime.

Simplified, EOS is the exposure of a component or PCB board to a current or voltage beyond its maximum ratings.  This exposure may or may not result in a catastrophic failure.

ElectoStatic Discharge (ESD) versus Electrical Overstress (EOS)
You can compare an ESD event with a knocked-over glass of water on a floor: you’ll get a small puddle but once all the water has spilt from the cup, it’s gone. There is no more water left and the damage is fairly limited. [Source]

ESD can be compared to a knocked-over glass of water
ESD can be compared to a knocked-over glass of water

However, an EOS event can be compared to an open tap; there may be just a little drip in comparison but there is an unlimited amount of water available. After a while, the entire floor may be flooded and could cause some serious damage. As you can see, EOS events last several magnitudes longer than most ESD events. [Source]

EOS can be compared to a dripping tab
EOS can be compared to a dripping tab

By many, ESD is seen as just one type of electrical stress. EOS on the other hand, describes a wide number of outcomes resulting from multiple stresses or root causes.

ESD does not require a “victim” or damaged product. There will be an ESD event if two objects are at different charge levels and a rapid, spontaneous transfer of an ElectroStatic charge between them occurs. An electrical stress can only become an overstress (as in EOS) if we’re aware of how much stress the “victim” (i.e. sensitive device) can withstand. One specification used to document these limits is the “Absolute Maximum Rating” (AMR). More on that in a little while. Back to EOS and ESD for now. The below image highlights the relationship and contrast between EOS and ESD:

Relationship between EOS and ESD
Relationship between EOS and ESD [Source]
Generally speaking, EOS describes extreme signals other than ESD. The following table lists the main differences:

  ESD Event EOS Event
Cause Rapid discharge of accumulated charge Voltage and/or currents associated with operation of equipment or with power generating equipment
Duration Once accumulated charge is consumed, ESD event can no longer manifest itself Lasts as long as originating signals; no inherent limitation
Characteristics Have specific waveform which includes rapid rising edge and asymptotic read edge Can have any physically possible waveform as sources of EOS are often unpredictable
Occurrence Non-periodic and non-repeatable (accumulation of charge cannot be guaranteed) Mostly (but not always) periodic and repeatable

Differences between EOS and ESD [Source]

The importance of Electrical Overstress (EOS)
Many failures in the electronics industry can be contributed to EOS. Yes, ESD has received a lot of attention over the past years. However, ESD represents only a small percentage of total EOS damages.

Typical causes of device failures
Typical causes of device failures [Source]
As explained further above, EOS and ESD are NOT the same thing. This is extremely important because:

  1. EOS damages are much more common compared to failures caused by ESD.
  2. A comprehensive ESD Control Program will provide protection against ESD but not EOS.

Now that you have learned what EOS is, how it’s different from ESD and that ESD protection is not effective for EOS damage, the obvious question will be “How can I protect my sensitive devices from EOS failures?”. That’s where we go back to our “Absolute Maximum Rating” (AMR) mentioned earlier.

Absolute Maximum Rating (AMR) and Electrical Overstress (EOS)
We’ve established earlier that EOS is caused by exceeding specific limits of a device, the so called Absolute Maximum Rating or AMR.
AMR represents “the point beyond which a device may be damaged by a particular stress” [Source].

Interpretation of AMR*
Interpretation of AMR* [Source]
*the yellow line represents the number of components suffering catastrophic damage

  • Region A is the safe operating area in which devices are to operate as anticipated.
  • Region B does not guarantee for the device to function as it should. No physical damage is expected in this area; however, if a device is operated in this region for extended periods of time, it may cause reliability problems.
  • The upper limit of region B represents the AMR. Issues will arise if a device is operated beyond this point.
  • Region C is the first area of electrical overstress causing latent failures.
  • Region D is the second area of electrical overstress causing immediate damages.

Protecting your sensitive devices from Electrical Overstress (EOS)
As already stated, ESD Protection measures are useless when it comes to protecting your sensitive devices from EOS. “Rather, improvement and mitigation of EOS failure causes will only advance through better communication between the supplier and the customer. This includes proper understanding of AMR, realistic specifications for it, finding the root cause of EOS damage incidents, and identifying the field and system application issues.” [Source]

References:

Introduction to ESD

Welcome to this little corner of the interwebs! Today marks the beginning of something truly amazing: our very own blog! You’re currently reading through our first blog post and we appreciate you taking time out of your busy life and spending it here.

The intention of this blog is to provide you with resources, information and tools – all focused around ESD! So, if you have any ideas for future blog posts or suggestions on what we could do better, don’t be a stranger and leave a comment! We look forward to hearing from you.

Now, for this first post we thought we’d start right at the beginning: what is ESD? It’s the core of our business but a lot of people don’t understand what it’s all about so let’s clear that up – right here and right now!

ElectroStatic Charge
Everything you see around you is made from atoms – your mouse, keyboard, screen, cup of coffee etc. Every atom is constructed of a nucleus, which includes positively charged protons, and one or more negatively charged electrons bound to the nucleus. As atoms have an equal number of electrons and protons, it balances out having no charge. No problems so far!

Structure of an AtomStructure of an Atom (Source)

Unfortunately, all materials can tribocharge and generate ElectroStatic charges. Most of the time this happens through contact and separation; some everyday life examples are:

  • Opening a plastic bag
  • Combing hair
  • Walking across a floor

Walking across a floor.pngWalking across a floor can generate an ElectoStatic Charge

For most people, static electricity is represented by the noise or crackle heard on a radio that interferes with good reception or the shock experienced when touching a metal object after walking across a carpeted room or sliding across a car seat. Static electricity is also observed as static cling when clothes are stuck together after coming out of a clothes dryer. Most of the time, people observe static electricity when the weather is cold and dry.” “While many people tend to think of static electricity as being at rest or not moving, static electricity causes the most concern when it ceases to be stationary.” [ESD Handbook ESD TR20.20 section 2.1 Basics of Static Electricity, Introduction]

When two materials make contact and are then separated, a transfer of electrons from one surface to the other may take place. The amount of static electricity generated depends upon the materials subjected to contact or separation, friction, the area of contact or separation, and the relative humidity of the environment. At lower relative humidity (as the environment is drier) charge generation will increase significantly. Common plastics generally will create the greatest static charges.
Electrostatic charge is most commonly formed by the contact and separation of two materials. The materials may be similar or dissimilar although dissimilar materials tend to liberate higher levels of static charge. An example is a person walking across the floor. Static electricity is produced when the person’s shoe soles make contact, then separate from the floor surface. Another example is an electronic device sliding into or out of a bag, magazine or tube.” [ESD Handbook ESD TR20.20 section 2.3 Nature of Static Electricity]

ElectroStatic Discharge (ESD)
If two items are at different ElectroStatic charge levels (i.e. one is positively and the other negatively charged) and approach one another, a spark or ElectroStatic Discharge (ESD) can occur. This rapid, spontaneous transfer of an ElectroStatic charge can generate heat and melt circuitry in electronic components.

ESD.png

ElectroStatic Discharge (ESD)

ESD events are happening around us all the time – yet, most of these cannot be seen or felt. For a person to sense ElectroStatic Discharge (ESD) (the dreaded ‘zap’), a discharge of about 2,000V is needed. To actually see ESD (in form of an arc, e.g. lightning) even greater voltages are required.

While ESD in your home can be annoying, it’s generally harmless. However, in the electronics industry ESD is the hidden enemy. Damages caused by invisible and undetectable ESD events can be understood by comparing ESD damage to medical contamination of the human body by viruses or bacteria. Although invisible, they can cause severe damage. In hospitals, the defense against this invisible threat is extensive contamination control procedures including sterilization. In the electronics industry, it’s ESD Protection; we will get into more detail on that in a later post.

Many of the common activities you perform daily may generate charges on your body that are potentially harmful to electronic components. Some of these activities include:

  • Walking across a carpet: 1,500V to 35,000V
  • Walking over untreated vinyl floor: 250V to 12,000V
  • Worker at a bench: 700V to 6,000V
  • Picking up a common plastic bag from a bench: 1,200V to 20,000V

Many of the CMOS technology components can be damaged by discharges of less than 1,000 volts. Some of the very sophisticated components can be damaged by charges as low as 10 volts.

Types of ESD Device Damage
So, we’ve established what ESD is and learned that ESD can damage electronics components. But what exactly does this damage look like? We’re so glad you asked!

The industry differentiates between catastrophic failures and latent defects. Per ESD Handbook ESD TR20.20 section 2.7 Device Damage – Types and Causes “Electrostatic damage to electronic devices can occur at any point, from the manufacture of the device to field service of systems. Damage results from handling the devices in uncontrolled surroundings or when poor ESD control practices are used. Generally damage can manifest itself as a catastrophic failure, parametric change or undetected parametric change (latent defect).

Catastrophic failures occur when a component is damaged to the point where it is DEAD NOW and will never again function. In these cases, the ESD event may have caused a metal melt, junction breakdown or oxide failure. This is the easiest type of ESD damage to find since it can be detected during inspection and testing.
When an electronic device is exposed to an ESD event it may no longer function. The ESD event may have caused a metal melt, junction breakdown, or oxide failure. The device’s circuitry is permanently damaged, resulting in a catastrophic failure.” [ESD Handbook ESD TR20.20 section 2.7.1 Catastrophic Failures]

Catastrophic Failures

Catastrophic failures will lead to completely failed or dead components.

Latent defects occur when ESD weakens or wounds the component to the point where it will still function properly during testing, but over time the wounded component may cause poor system performance. Later, after final inspection, perhaps in the hands of your customer, a latent defect may become a catastrophic failure.
A device that is exposed to an ESD event may be partially degraded, yet continue to perform its intended function. However, the operating life of the device may be reduced dramatically. A product or system incorporating devices with latent defects may experience a premature failure after the user places them in service. Such failures are usually costly to repair and in some applications may create personnel hazards.” It is easy with the proper equipment to confirm that a device has experienced catastrophic failure or that a part is degraded or fails test parameters. Basic performance tests will substantiate device damage. However, latent defects are virtually impossible to prove or detect using current technology, especially after the device is assembled into a finished product. Some studies claim that the number of devices shipped to users with latent defects exceeds the number that fail catastrophically due to ESD in manufacturing.” [ESD Handbook ESD TR20.20 section 2.7.2 Latent Defects]

Latent Defects

Latent defects lead to degraded or wounded components

Costly Effects of ESD
Catastrophic failures are straight forward: they can be detected and repaired at an early manufacturing stage. This is the least costly type of ESD damage.

Latent defects on the other hand are not only hard to find, but they can also severely affect the reputation of your company’s product. Latent defects can cause upset or intermittent failures and can be very frustrating: customers return a product with a problem which the factory fail to detect so it ends up at the customer’s again with the problem unresolved.

ESD Damage on an Integrated Circuit

The cost for repairing latent defects increases as detection of the failure moves through the system. One study indicated the repair cost to be:

  • $10 Device
  • $10 Device in board: $100
  • $10 Device in board and in system: $1,000
  • $10 Device and system fails: $10,000

Industry experts estimate that product losses in the electronics industry due to static discharge range from 8 to 33%. Others believe the actual cost of ESD damage amount to billions of dollars annually.

Conclusion
ESD is the hidden enemy in the electronics industry:

  • It cannot be felt
  • It cannot be seen
  • It cannot necessarily be detected through normal inspection procedures.

Therefore, it is absolutely crucial to be aware of the most sensitive items in your factory. Technology advances all the time: electronic circuitry gets progressively smaller which leads to a reduction of microscopic spacing of insulators and circuits within components. “Electronic items continued to become smaller, faster and their susceptibility to static damage increased…all electronic devices required some form of electrostatic control to assure continued operation and product reliability.” [ESD Handbook ESD TR20.20 section 2.2]. While this is great news for the consumer with better, faster and stronger computers, tablets, phones etc., it’s bad news for the manufacturers. The evolution of technology leads to devices being even more sensitive to ESD. As a result, the need for appropriate ESD Protection is now more important than ever.

Over the next few weeks, we will provide you with all the tips, tools and techniques to create an effective ESD Control Program so that your sensitive components are protected against damages from ESD.