ESD Sensitive Items

Measuring Effectiveness of an ESD Control Program

Introduction

Electronic devices and systems can be damaged by exposure to high electric fields as well as by direct electrostatic discharges. A good circuit layout and on-board protection may reduce the risk of damage by such events, but the only safe action at present is to ensure that devices are not exposed to levels of static electricity above the critical threshold.

This can only be achieved by introducing a static control program which usually involves setting up an ESD Protected Area (EPA) in which personnel are correctly grounded and all meet the ESD Standard. However, setting up an EPA does not of itself guarantee a low static environment. Production procedures may change, new materials may be introduced, the performance of older materials may degrade and so on.

Measuring Effectiveness of an ESD Control Program

To ensure the effectiveness of any static control program it is important that regular measurements are carried out:

  1. to determine the sensitivity to ESD of devices being produced or handled.
  2. to confirm that static levels are lower than the critical level, and that new or modified work practices have not introduced high static levels.
  3. to ensure that both new and existing materials in the EPA meet the necessary requirements.

Only after an ‘operational baseline’ has been established by regular auditing will it become possible to identify the origin of unexpected problems arising from the presence of static.

1. Determining the sensitivity of ESD sensitive Devices

It is important to understand the sensitivity of ESD sensitive devices before an action plan can be created. Once you know the sensitivity of the items you are handling, can you work towards ensuring you’re not exceeding those levels.

Part of every ESD control plan is to identify items in your company that are sensitive to ESD. At the same time, you need to recognize the level of their sensitivity. As explained by the ESD Association, how susceptible to ESD a product is depends on the item’s ability to either:

  • dissipate the discharge energy or
  • withstand the levels of current.

2. Measurements to prove the effectiveness of an ESD Control Program

Measuring electrostatic quantities poses special problems because electrostatic systems are generally characterized by high resistances and small amounts of electrical charge. Consequently, conventional electronic instrumentation cannot normally be used.

Measuring Electrical Field

Wherever electrostatic charges accumulate, they can be detected by the presence of an associated electric field. The magnitude of this field is determined by many factors, e. g. the magnitude and distribution of the charge, the geometry and location of grounded surfaces and the medium in which the charge is located.

The current general view of experts is that the main source of ESD risk may occur where ESDS can reach high induced voltage due to external fields from the clothing, and subsequently experience a field induced CDM type discharge.” [CLC TR 61340-5-2 User guide Garments clause 4.7.7.1 Introductory remarks]

718_Use2.jpg
Using the 718 Static Sensor to test static fields

A static field meter is often used for ESD testing of static fields. It indicates surface voltage and polarity on objects and is therefore an effective problem-solving tool used to identify items that are able to be charged.

A field meter can be used to:

  • verify that automated processes (like auto insertion, tape and reel, etc.) are not generating charges above acceptable limits.
  • measure charges generated by causing contact and separation with other materials.
  • demonstrate shielding by measuring a charged object and then covering the charged item with an ESD lab coat or shielding bag. Being shielded the measured charge should be greatly reduced.

 

Measuring ESD Events

ESD events can damage ESD sensitive items and can cause tool lock-ups, erratic behavior and parametric errors. An ESD Event Detector like the EM Eye ESD Event Meter will help detect most ESD events. It detects the magnitude of events and using filters built into the unit, it can provide approximate values for some ESD events for models (CDM, MM, HBM) using proprietary algorithms.

Using the EM Eye ESD Event Meter to detect ESD Events

Solving ESD problems requires data. A tool counting ESD events will help carry out a before-and-after analysis and will prove the effectiveness of implementing ESD control measures.

 

3. Checking Materials in your EPA

When talking about material properties, the measurement you will most frequently come across is “Surface Resistance”. It expresses the ability of a material to conduct electricity and is related to current and voltage. The surface resistance of a material is the ratio of the voltage and current that’s flowing between two pre-defined electrodes.
It is important to remember that the surface resistance of a material is dependent on the electrodes used (shape as well as distance). If your company implements an ESD control program compliant to the ESD Standard ANSI/ESD S20.20, it is therefore vital to carry out surface resistance measurements as described in the Standard itself. For more information on the definition of resistance measurements used in ESD control, check out this post.

A company’s compliance verification plan should include periodic checks of surfaces measuring:

  • Resistance Point-to-Point (Rp-p) and
  • Resistance-to-ground (Rg).
SRMeter2_use.jpg
Measuring Surface Resistance of worksurface matting using the
SRMETER2 Surface Resistance Meter

Surface resistance testers can be used to perform these tests in accordance with ANSI/ESD S20.20 and its test method ANSI/ESD S4.1; if these measurements are within acceptable ranges, the surface and its connections are good. For more information on checking your ESD control products, catch-up with this. It goes into depth as to what products you should be checking in your EPA and how they should be checked.

 

Conclusion

Measurements form an integral part of any ESD control program. Measuring devices help identify the sensitivity of ESD devices that ESD programs are based on, and also are used to verify the effectiveness of ESD control programs set in place. High quality instruments are available commercially for measuring all the parameters necessary for quantifying the extent of a static problem.

We hope the list above has introduced the techniques most commonly used. For more information on how to get your ESD control program off the ground, Request a free ESD/EOS Assessment at your facility by one of our knowledgeable local representatives to evaluate your ESD program and answer any ESD questions!

 

 

Storage and Transport of ESD Sensitive Items

In our last post, we talked about the ESD protective packaging requirements for ESD sensitive items and provided you with 6 steps to choose the correct type of packaging. We thought today we could go in a little bit more detail and introduce you to some types of packaging and how to use them. If you read our recent post on Tips to Fight ESD, you will remember how important it is to protect your ESD sensitive items when leaving an EPA. Yet, too often we see customers who have the perfect EPA, but when it comes to transporting and storing their precious components, it’s all falling apart.

Packaging required for transporting and storing ESD sensitive items
During storage and transportation outside of an EPA, it is recommended that ESD sensitive components and assemblies are enclosed in packaging that possesses the ESD control property of shielding. See our last post for more details.

Remember:

  • In ‘shielding’ we utilize the fact that electrostatic charges and discharges take the path of least resistance.
  • The charge will be either positive or negative; otherwise the charge will balance out and there will be no charge.
  • Charges repel so electrostatic charges will reside on the outer surface.

The Faraday Cage effect
A Faraday Cage effect can protect ESD sensitive items in a shielding bag or other container with a shielding layer. To complete the enclosure, make sure to place lids on boxes or containers and close shielding bags.

Cover must be in place to create Faraday Cage and shield contents.

Types of shielding packaging
The below list gives a few examples of what types of shielding packaging is available on the market. This list is by no means complete; there are many different options out there – just make sure the specifications state “shielding” properties.

  • Metal-In Shielding Bags
    ESD bags which protect ESD sensitive items. The ESD shielding limits energy penetration from electrostatic charges and discharge. They offer good see-through clarity. Available with and without zipper.

    Example of a Metal-In Shielding Bag – Click here for more information
  • Metal-Out Shielding Bags
    Integral antistatic and low tribocharging bags which will not electrostatically charge contents during movement. Bags have an aluminium metal outer layer of laminated film. Available with and without zipper.

    Example of a Metal-Out Shielding Bag – Click here for more information
  • Moisture Barrier Bags
    Offer ESD and moisture protection and can be used to pack SMD reels or trays.

    Example of a Moisture Barrier Bag – Click here for more information
  • Cushioned Shielding Bags
    These bags combine the “Faraday Cage” and mechanical protection. They shield about twice as well as normal shielding bags of equivalent size.

    Example of a Cushioned Shielding Bag – Click here for more information

Additional options for storing ESD sensitive items
Do you have the following in place?

  • ESD flooring
  • Grounded personnel (using foot grounders)
  • Grounded racking

IF (and this is a BIG IF) the above requirements are fulfilled, you can use conductive bags or containers to store your ESD sensitive items. Conductive materials have a low electrical resistance so electrons flow easily across the surface. Charges will go to ground if bags or containers are handled by a grounded operator or are stored on a grounded surface.

Conductive materials come in many different shapes and forms:

Conductive Black Bags
Tough and puncture resistant bags which are made of linear polyethylene with carbon added. The bags are heat sealable.

Example of a Conductive Black Film – Click here for more information
  • Rigid Conductive Boxes
    Provide good ESD and mechanical protection. Boxes are supplied with or without high density foam for insertion of component leads or low density foam which acts as a cushioning material.
  • PCB Containers
    Are flat based and can be stacked. They are made of injection moulded conductive polypropylene.

Again, there are many more options available on the market so make sure you do your research.

Note: we do not recommend using conductive packaging to transport ESD sensitive devices. Also, pink antistatic and pink antistatic bubble bags are not suited for storing or transporting ESD sensitive components.

Final thoughts
Packaging with holes, tears or gaps should not be used as the contents may be able to extend outside the enclosure and lose their shielding as well as mechanical protection.

Also, do not staple ESD bags shut. The metal staple provides a conductive path from the outside of the ESD bag to the inside. The use of a metal staple would undermine the effectiveness of the ESD bag making a conductive path for charges outside the bag to charge or discharge to ESD sensitive components inside the bag. To close an ESD bag, it is recommended to heat seal or use ESD tape or labels after the opening of the bag has been folded over. Alternatively, you can use ESD bags with a zipper.